Menu icon
×

Error Codes & Solutions - Tall Control Panel

PDF iconPrintable PDF
Error Number Meaning Solution
EC08 Pll bar Need to confirm design on screen
ED09 Back to the beginning, then pull backward bar again The operating error.
EC11 No such design in memory Select another design.
EC12 Main shaft not stopped in position  
EC13 Frame over border Frame out of sewing field – Turn off and manually move with hands to center.
EC14 Part of memory lost  
EC16 Sep motor
  1. Check mechanical transmission.
  2. Check X Y motor.
  3. Check X Y driver.
EC17 Color changing overtime
  1. Check the color motor. Check motor driver board PC501/PC502.
  2. Check the sensor.
EC18 Color changing half rotation abnormal Adjust by turning the handwheel by hand.
EC19 Need position abnormal  
EC20 Main motor overtime  
EC21 Color changing out "Needles" parameter setting must equal to the machine's actual needles. 9 or 12 or 15.
EC26 Trimming not in position Check whether the detection sensor is damaged.
EC41 Files not in disk
  1. Try again.
  2. Restart machine and then try again.
  3. Execute "Clear All Designs".
EC42 Disk dir full Delete some designs to free memory.
EC43 Disk space full Delete some designs to free memory.
EC44 File distribution list error Execute "Clear All Designs".
EC45 Dir error Execute "Clear All Designs".
EC208   The same method as EC20.
Share this page: